E22 (Low Power Output)

Prepared by:

 EH

Approved by:

 

Valid from:

 280426

Document no.:

 

Rev. no.

 


1. Error Overview

 

Definition: The output power has been lower than minimum limit for more than 3 seconds.

 

2. Symptom Checklist

  • Error code is displayed on the iPM Generator and external controllers.

3. Potential Root Causes

  • Electrode Gap too Large
  • Break in the discharge circuit
  • Defective Generator
  • Defective Transformer

4. Step-by-Step Resolution

5. Escalation


If you have completed this guide and are still experiencing issues please contact Support for further investigation.