| E22 (Low Power Output) | ||||
Prepared by: EH | Approved by:
| Valid from: 280426 | Document no.:
| Rev. no.
| |
1. Error Overview
Definition: The output power has been lower than minimum limit for more than 3 seconds.
2. Symptom Checklist
- Error code is displayed on the iPM Generator and external controllers.
3. Potential Root Causes
- Electrode Gap too Large
- Break in the discharge circuit
- Defective Generator
- Defective Transformer
4. Step-by-Step Resolution
- Check the gap of the electrodes to the base roller
- Inspect wiring to find breaks withing the system.
- HP cable
- Electrode Wires
- Transformer connections
5. Escalation
If you have completed this guide and are still experiencing issues please contact Support for further investigation.